DIAGNOSTIC MODE
To display diagnostic readings on the controller:
• If the platform is positioned above oor level
(FIG. 84-1), press the UP button on the hand
pendant (FIG. 84-2) rapidly 11 times.
• If the platform is positioned below oor level
(FIG. 84-3), press the FOLD button on the
hand pendant (FIG. 84-4) rapidly 11 times.
HAND PENDANT
FIG. 84-2
UP
PLATFORM ABOVE FLOOR
LEVEL (STOWED)
FIG. 84-1
HAND PENDANT
FIG. 84-4
PLATFORM BELOW FLOOR LEVEL
FIG. 84-3
FOLD
CAUTION
CAUTION
Leaning on any part of the Lift
while doing this procedure could
result in personal injury and affect
some of the diagnostic readings on
the controller.
!